 $ mou/over=id msa0:


%MOUNT-I-MOUNTED, CDD mounted on _MSA0:


 $ dir/siz msa0:

Directory MSA0:[]

CDD031.A;1              125

Total of 1 file, 125 blocks.


 $ dism/nounl msa0:


 $ @sys$update:vmsinstal cdd031 msa0:


        VAX/VMS Software Product Installation Procedure V4.7    


It is 23-SEP-1986 at 14:18.
Enter a question mark (?) at any time for help.

* Are you satisfied with the backup of your system disk [YES]? 

Please mount the first volume of the set on MSA0:.
* Are you ready? yes


%MOUNT-I-MOUNTED, CDD mounted on _MSA0:

The following products will be processed:

  CDD V3.1


        Beginning installation of CDD V3.1 at 14:18

%VMSINSTAL-I-RESTORE, Restoring product saveset A...
* Do you want to print the CDD 3.1 release notes [YES]? no

   A copy of the CDDRLSE.MEM will be saved in SYS$UPDATE.

   The CDD$DICTIONARY  system logical name is used to identify the 
   location of the root dictionary file.

   The equivalence string for CDD$DICTIONARY must resolve to a device
   and directory (e.g. DBA0:[SYSEXE]).  You should pick a directory on
   a disk that is always mounted.  We suggest the [SYSEXE] directory on
   your system disk.

   Simply press the RETURN key for the following question if you want
   the dictionary to be placed in SYS$SYSTEM.

* Enter the root dictionary file's device and directory: [SYS$SYSTEM]: 

* Do you want to run the IVP after the installation [YES]? 

   When you run the IVP from VMSINSTAL, the IVP
   creates a log file, CDDIVP.LOG.  When the IVP runs
   successfully the log file is deleted, unless you
   explicitly request that it be saved.  If an error
   occurs while running the IVP, the log file is 
   saved in SYS$UPDATE.

* Do you want to print the log file from the IVP [NO]? YES

* Do you want to save the log file from the IVP [NO]? 

* Do you want to purge files replaced by this installation [YES]? 


   The installation procedure has asked all the questions
   required to complete the installation.


    Don't forget to edit the system manager's SYSTARTUP.COM file to
   submit the SYS$MANAGER:CDDSTRTUP.COM file when the system is booted.

%VMSINSTAL-I-MOVEFILES, Files will now be moved to their target directories...
 
        IVP running .... 
%DMU-E-CDDERROR, CDD error at "_CDD$TOP.CDD$EXAMPLES"
-CDD-E-NODNOTFND, directory or object not found

   This error was received because the IVP checked for the
   existence of the directory CDD$EXAMPLES and it was not
   found.  The IVP will create CDD$EXAMPLES and continue the
   test.


        The IVP succeeded.
%PRINT-F-CREJOB, error creating job
-JBC-E-JOBQUEDIS, system job queue manager is not running

        Installation of CDD V3.1 completed at 14:19



        VMSINSTAL procedure done at 14:19




 $